HYUNDAE G4D





::: DIESEL ENGINE GENERATING SET :::

       
       
       
 
 
GM4AF(FOR MARINE), G4D(FOR LAND)
 
Diesel Engine
- Type : 4-stroke, 4-cylinder, vertical, fresh water-cooling diesel engine
- Continuous output : 54PSx1800RPM, 45PSx1500RPM
- Cylinder bore x stroke : 100mmx105mm(3.94x4.13 in)
- Displacement : 3298 cc (201.3 cu. inch)
- Aspirator : Natural aspirator


Generator
- Continuous output : 40KWx1800RPM, 33kWx1500RPM)
- Voltage : 220V, 380V, 440V
- Phase x Wire : 3phasex4wire
- Power factor : 0.8
- Insulating class : H
 
Model : GM4AF(FOR MARINE), G4D(FOR LAND)
Continuous Output : 33KW x 1,500RPM, 40KW x 1,800RPM
 
-Approval by the Korean Institute of Ship Safety & technology.
-Acquired ISO 9001.
-Acquired "Q" marking from government.
-Acquired "GQ" marking from government.
 
1. Stable output about 3 %load-regulation
2. High output with the comparison of the same class diesel generators
3. Economical generators and parts, easy maintenance
4. Best designed and manufactured of all auxiliaries engines. Available for multi purpose from overland power to power supply,to emergency power. (Special order and manufacture at low cost)
5. Large capacity heat exchanger under the tropical zone for the safe operation
6. Use of high quality engine protection devices and instrument panels
 
 

[ 피뢰기의 기능 ]
피뢰기는 선로를 타고 들어오는 이상전압을 신속히 대지로 방류하여 전력기기를 보호하는 기기이다.

 

 

 

[ 피뢰기의 동작 책무 ]
이상전압 침입시 신속하게 방전할 것
이상전류 통전시 단자전압을 일정전압 이하로 억제할 것
이상전압 해소 후 속류를 차단하여 자동 회복할 것
반복 동작에 대해 특성이 변하지 않을 것

[ 피뢰기를 신설하여야 하는 장소 ] - 전기설비기술기준 제46조
발전소,변전소 또는 이에 준하는 장소의 가공전선 인입구 및 인출구
가공전선로에 접속하는 기준 제32조의 배전용변압기의 고압측 및 특별고압측
고압 및 특별고압 가공전선로로 부터 공급을 받는 수용장소의 인입구
가공전선로와 지중전선로가 접속되는 곳

[ 피뢰기의 적용 ]

※ 피뢰기의 정격 전압
 

전 력 계 통

피뢰기 정격 전압 (KV)

전압(KV)

중성점 접지

변전소

배전선로

345

유효접지

288

-

154

유효접지

138

-

66

PC접지 또는 비접지

75

-

22

PC접지 또는 비접지

24

-

22.9

3상 4선식 다중접지

21

18

11.4

3상 4선식 다중접지

12

9

5.7

3상 4선식 다중접지

7.5

7.5

6.6

비접지

7.5

7.5

3.3

비접지

7.5

7.5(4.2)


※ 설치 장소별 피뢰기 공칭 방전 전류
 

공칭방전전류

설치장소

적 용 조 건

10,000A

발전소

전발전소

변전소

1. 154KV이상 계통

2. 66KV 및 그 이하의 계통에서 bank 용량이 3,000 KVA를 초과하거나
특히 중요한 곳

3. 장거리 송전선 케이블(배전“휘다”인출용 단거리 케이블 제외) 및 정전 축전기 bank를 개폐하는 곳

5,000A

변전소

66KV 및 그 이하 계통에서 bank 용량이 3,000KVA 이하

2,500A

선로변전소

배전선로 배전선 “휘다” 인출측


(주) 전압 22.9KV 이하(22KV 비접지 제외)의 배전선로에서 수전하는 설비의 피뢰기 공칭 방전 전류는 일반적으로 2,500A의 것이 적용된다.


[피뢰기 구조의 종류]
 

① 방전갭

② 바리스터

③ 밸브형 어레스터

④ 병렬형 어레스터

 

[ 피뢰기 구조의 장단점]

종별 / 장단점

장 점

단 점

1. 방전갭

서지 전류 흡수능력이 크다

약 100(kA)

응답 속도가 늦다

속류 발생의 우려가 있다

2. 바리스터

응답 속도가 빠르다

제한 전압을 낮게 할 수 있다

속류도 일단은 차단한다

서지 흡수 능력이 적다

누설 전류가 있다

쇼트 모드 고장이 있다

3. 밸브형피뢰기

서지 전류 흡수 능력이 크다

속류를 확실하게 차단한다

응답 속도가 비교적 느리다

4. 병렬형피뢰기

응답 속도가 빠르다

서지 전류 흡수 능력이 크다

속류를 확실히 차단한다

제한 전압의 협조가 어렵다

(소자와 캡)

2. 서지흡수기

[ 서지흡수기의 기능 ]

사용자 삽입 이미지
 

서지 흡수기는 피뢰기가 뇌격 보호인데 비해 개폐서지 보호용으로 주로 몰드변압기 채택시 VCB 후단 변압기 전단에 설치하여 VCB 개폐서지로부터 BIL 이 낮은 몰드변압기를 보호하기 위해 설치한다.

[ 서지흡수기의 적용 ]
※ 서지 흡수기의 정격

공칭전압

3.3(kV)

6.6(kV)

22.9(kV-Y)

정격전압

4.5(kV)

7.5(kV)

18(kV)

공칭방전전류

5(kA)

5(kA)

5(kA)


  차단기 종류

VS

VCB

전압등급  2차 보호기기
3(kV)
6(kV)
3(kV)
6(kV)
10(kV)
20(kV)
30(kV)

발전기  

불필요
부분적으로 검토 적용

-

-

-

발전기

유입식

불필요

불필요

불필요

불필요

불필요

불필요

몰드식

불필요

반드시적용

반드식적용

반드식적용

반드식적용

반드시적용

건  식

불필요

반드시적용

반드시적용

반드식적용

반드시적용

반드시적용

콘덴서

불필요

불필요

불필요

불필요

불필요

불필요

변압기와유도기기와의 혼용 사용식

불필요

반드시적용

반드시적용

-

-

-

(주) 상기표에서와 같이 VS 또는 VCB를 사용시 반드시 서지흡수기를 설치해야 하나 VCB 와 유입변압기를 사용시설치하지 않아도 된다.

[ LA와 SA의 차이점 ]
서지파형의 비교



직격뢰, 유도뢰등에 의한 뇌서지는 파고치가 크고 급준파로서 서지의 파두장 이
     수 ㎲ 파미장이 수십 ㎲ 이다.

개폐서지의 파고치는 뇌과전압 보다 작지만 지속 시간이 파두장 50-500㎲
     파미장 2-10(mS)로 길다.
     대표적인 개폐서지로는 진공차단기 등과 같은 차단 성능이 좋은 차단기로 지연
     소전류를 차단하면 전류 “0”점이 되기전에
     차단하여 전류 재단 현상이 생기고 이때 발생되는 서지는 BIL이 낮은 건식류의
     기기를 소손할 우려가 있다.

* 피뢰기(방전갭에서 시작)
방전갭에서 시작하여 직렬갭과 특성 요소를 결합한 구조의 것이 사용되었으나 뛰어난 비직선저항 특성을 가진 ZnO 소자가 개발되어 최근 피뢰기에 사용되고 있다.

* 서지흡수기(C-R형 필터에서 시작)
C-R형 서지흡수기가 대표적으로 콘덴서의 고주파에서 임피던스가 낮아지는 성질을 이용한 서지필터가 사용되었으나 고압 이상에서 부터 ZnO 소자를 적용한 서지 흡수기가 사용되고 있다.

따라서 피뢰기와 서지흡수기의 구조가 거의 같고 구분이 모호해지고 있으나 구태      나눈다면 피뢰기가 뇌격 보호용으로
    일정전압 이상의 급준파에 대응한다면 서지흡수기는 설계 전압 범위가 있고 뇌격에
    비해 완만하고 지속시간이 긴 개폐서지 등의 이상전압에 대응하는 옥내 피뢰기이다.

Lighting Arrester : 뇌보호용 피뢰기
Surge Absorbor : 서지흡수기 C-R형
Surge Arrester : 서지흡수용 피뢰기 ZnO형


계기용변성기

1. 계기용 변성기의 기능
계기용 변성기는 주회로의 고전압. 대전류를 사용 목적에 적당한 저전압. 소전류로 변성하여 계기나 계전기를 소형화하고 취급을 용이하게 하기 위함이다. 계기용 변성기를 잘못 선정하거나 결선이 바르지 않으면 보호장치나 계측 장치가 무용지물이 될 우려가 있으니 선정에 주의해야 한다

2. 계기용 변성기의 종류
계기용 변성기를 용도에 따라 분류하면 변류기, 변압기로 나눌 수 있고, 절연 형태로는 건식, 유입식, 몰드식으로 구분되며 최근 22.9KV급에 방재화에 유리한 몰드식이 많이 적용되고 있다.

 [계기용 변성기 :MOF]

 

[건식 MOF]
[유입식 MOF]
   

① MOF의 기능
MOF는 전력수급용 삼상 계기용 변류기를 말하며, 고전압 대전류를 저전압 저전류(110V,5A)로 변성하여 전력량계에 공급하여 한전과 수용가와의 전력요금 계산에 필요한 기기이다.

* 고전압 대전류를 그대로 계측하는 것은 곤란하고 설혹, 22.9KV에 100A 를 견딜 수 있는 전력량계가 있다면 절연 때문에
   부피와 중량이 크고 가격도 무척 비쌀것이다. 또 그러한 위험한 계량기의 검침은 누가 할것인가.

② MOF의 과전류 강도
MOF의 과전류 강도에는 열적과전류 강도와 기계적과 전류 강도가 있고 과전류 강도가 부족한 MOF는 단락사고시 파손 또는 폭발할 우려가 있다.

전류비별 과전류 강도
 

전류비

과  전  류  강  도  ( 배 수 )

5/5A

75배수  150배수  300배수

10/5A

75배수 150배수

15/5A

75배수 150배수

20/5A

75배수

30/5A

40/5A

50/5A

60/5A

75/5A

40배수

100/5A

150/5A

200/5A

250/5A

300/5A

400/5A

500/5A

600/5A

750/5A

* 지정전류 영역(5/5A, 10/5A, 15/5A)에 있어서 과전류 강도

(22.9kV 계통 가공전선로 기준)

구분

~1Km

~3Km

~5Km

~7Km

~10Km

~20Km

5/5A

300배수

150배수

75배수

10/5A

150배수

75배수

15/5A

150배수

75배수

* Km는 한전 변전소에서부터 수용가까지의 가공전선로 길이

③ 과전류 강조의 중요성
MOF는 작은 용기내에 계기용 변류기와 계기용 변압기가 수납된 구조로 고압기기 중 가장 취약한 기기이다.
과전류 강도가 부족한 MOF를 계속 사용하면 평상시에는 지장이 없다가, 수용가 구내 단락시 단락과전류를 견디지 못하고 MOF가 소손되거나 폭발하여 화재로 발전하는 경우도 있다. 따라서 과전류 강도가 부족하면 즉시 교체해야 하고
한국전기안전공사에서는 기존 설비라 하더라도 2006. 12. 19일 이후 불합격 처리하도록 되어있다.
예전에는 우리나라 발전 송전 설비용량이 작고 고압수용가 또한 적어서 MOF 과전류 강도를 중요하게 취급하지 않았으나, 발전 및 송전용량이 증가하고 한전
변전소의 신설로 수용가에서 한전 변전소간 거리가 가까워져 수용가까지의 % 임피던스가 감소하여 각 수용가의 단락용량이 커지게 되면서 MOF의 과전류 강도가 중요하게 인식되고 있다.



계기용 변성기에 대해서..

계기용 변성기는 고전압, 대전류가 직접 배전반에 있는 계기나 계전기에 연결되면
 대단히 위험하므로 전압, 전류에 비례하는 저전압(110[V]), 소전류(5[A], 1[A],
 0.1[A])로 변성하여 계측기나 보호 계전기 등의 입력 전원으로 사용하기 위한 기기
이다.

계기용 변성기에는 계기용 변압기(PT, VT), 계기용 변류기CT),
계기용 변압변류기(PCT, VCT, MOF), 영상변류기(ZCT) 등이 있다.


1) 계기용 변압기 (PT: potential transformer)

계기용 변압기는 고압 회로의 전압을 이에 비례하는 낮은 전압으로 변성해 주는
 기기로서, 회로에 병렬로 접속하여 사용하며, 배전반의 전압계, 전력계, 주파수계,
 역률계, 표시등 및 부족전압 트립코일(UVC)의 전원으로 사용된다.

계기용 변압기의 정격부담이란 변성기의 2차측 단자간에 접속되는 부하의 한도를
 말하며 [VA]로 표시한다.


계기용 변압기(PT) 정격

계기용 변류기(CT)정격

1차 정격전압[V] 3300, 6600,22900 1차 정격전류[A] 10,15,20,40,50,75,100,150,200
2차 정격전압[V] 110 2차 정격전류[A] 5
정격부담[VA] 50, 100, 200, 4000 정격부담[VA] 15, 40, 100

                   

사용자 삽입 이미지
사용자 삽입 이미지


2) 계기용 변류기(CT: current transformer)

계기용 변류기는 회로에 흐르고 있는 전류가 크면 접속하는 전선이나 케이블이
굵어지게 되어 계기를 부착하기가 곤란할 뿐 아니라 위험하므로, 이에 비례하는
소전류로 변성해 주는 기기로서 회로에 직렬로 접속하여 사용하며, 배전반의
전류계, 전력계, 차단기 트립 코일의 전원으로 사용한다.

         

사용자 삽입 이미지
사용자 삽입 이미지

3) 계기용 변압 변류기 (MOF 또는 PCT: metering of fit)

계기용 변압 변류기는 계기용 변압기와 변류기를 조합한 것으로 전력 수급용
전력량을 측정하기 위한 기기이다.


 

사용자 삽입 이미지

사용자 삽입 이미지


4) 영상 변류기(ZCT: zero-phase current transformer)

영상 변류기는 회로에 지락사고가 발생했을 때 흐르는 영상전류(지락전류)를 검출하여 접지 계전기에 의해 차단기가 동작하도록 하는 기기이다.


그 밖에



[ 계기용변류기 (CT) ]
 

계기용 변류기는 대전류를 소전류로 변성하는 것으로 보통 정격 2차 전류는 5A 이다.
 이것은 계기, 계전기의 입력이 5A로 설계되기 때문이다. 또한 계기용 변류기 선정시 계급, 정격전압, 정격1차전류, 정격2차전류, 과전류강도, 과전류정수 등을 잘 이해하고 사용해야 한다.

[ 계기용변압기 (PT) ]



계기용 변압기는 어떤 전압(주로 고압)을 저압(110V)으로 변성하여 계기, 계전기에 공급하는 것으로 CT와 마찬가지로 적용에 주의해야 한다.

 [ GPT, ZCT ]

 
[영상변류기]
 
[접지형 계기용 변압기]
     
GPT는 접지형 계기용 변압기로 3.3KV. 6.6KV, 22KV 등 비접지 계통에서 지락 검출을 위한 영상 전류를 얻기 위해 사용한다.

ZCT는 1개의 부하회로 각상을 모두 내부에 관통시켜 지락 전류를 검출하는 것으로
고저항 접지의 고압 계통에서 주로 사용하고 저압의 것은 주로 배전반에서 각 간선 회로에 설치하여 누전경보기와 조합하여 지락 경보 목적으로 사용된다.

 
보호계전기

1. 보호계전기
보호계전 시스템은 전력 설비의 사고를 재빨리 검출, 제거하여 사고의 확대나 파급을 방지하기 위한 보호 계전기를 주축으로 한 시스템으로, 보호 계전기는 CT, PT 등에서 검출된 전압, 전류를 설정값과 비교하여 고장이라고 판단되면 차단기 등에 트립지령을 주는 것으로서 보호계전기 선정이나 정정이 잘못되면 보호 계전 시스템이 무용지물이 된다.

2. 보호계전기의 종류




[여러가지 보호계전기들]


[ 동작구조별 ]

전자기계형 : 유도 원판형으로 대표되고 구동력은 전자 기계력에 의해 직접 얻는다.
정지형 : 트랜지스터등의 소자를 이용한 것으로 동작 속도가 빠르고 가동 부분이
                 없어서 오동작이 적고 진동에 강하다.
디지털형 : 반도체 소자를 사용하여 정밀도가 높고 감시 제어 장치와 연결이 쉽다.

[ 동작종류별 ]

  과전류 계전기 (OCR)
전류가 어느 설정값 이상일 때 응동하여 동작하며 과부하 보호 목적으로 사용한다.

과전압 계전기 (OVR)
전압이 어느 설정값 이상일 때 응동하여 동작하며 과전압에 의한 기기 소손 방지를 위해 사용한다.

지락과 전류 계전기 (OCGR, GOCR)
지락 전류가 어느 설정값 이상일 때 동작하는 것으로 22.9KV 계통에서는 잔류회로 전류를 검출한다.

부족전압 계전기 (UVR)
전압이 어느 설정값 이하 또는 정전일 때 동작하여 기기를 보호하거나 비상용 발전기를 기동시키기 위해서 사용한다.

비율차동 계전기
변압기 1차, 2차 전류를 비교하여 변압기 내부 고장을 검출하는 계전기로 대용량 변압기나 중요 변압기에 설치한다.

역전력 계전기
열병합 설비를 갖춘 곳에서 수용가의 발전 전력이 한전측으로 역 송전되지 못하게 할 때 사용한다.

지락방향 계전기 (DGR, SGR)

3.3KV, 6.6KV, 22KV 등 비접지 계통에서의 지락 보호에 사고 선로만 선택 차단하기 위해 적용된다.

기타 계전기
거리계전기, 주파수계전기 등 여러 계전기가 사용 목적에 따라 각각 단독으로 또는 조합되어 사용되고 있다.[ 동작시한별 ]
순시, 정한시, 반한시, 단한시 등이 사용 목적에 따라 여러 가지가 있다.

3. 보호계전기의 구비 조건

정확성

신뢰도가 높고 정확한 동작으로 오동작이 없어야 한다.

신속성
주어지 조건에 도달할 경우 신속하게 동작해야 한다.

선택성
선택차단 및 복구로 정전 구간을 최소화 할 수 있어야 한다.

기타
취급이 간단하고 보수가 용이 할 것.
주위 환경에 동작 성능의 영향을 적게 받을 것.
정정, 변경이 용이 할 것.


전력용콘덴서

 

1. 전력용콘덴서



일반적으로 전력부하는 저항과 유도성 리엑턴스로 이루어져 있으므로 회로에 흐르는 전류는 지연 무효 전류를 여분으로 흐르게 하여 여러 가지 장해를 가져오므로 회로에 앞선 무효 전력을 공급할 필요가 있고 이것을 역률 개선이라고 하고 앞선 무효 전력을 공급하는 기기가 콘덴서이다. 콘덴서는 역률 개선 효과 이외에도 고주파에서의 낮은 임피던스로 인한 필터효과, 직류에서의 전력 저장 효과도 있으나 전력용 콘덴서라 함은 역률 개선용 콘덴서를 말한다.

2. 역률개선 효과

 

[ 변압기 손실 경감 ]
변압기 손실은 철손과 동손으로 구분되고 동손은 전류의 제곱에 비례하므로 변압기 권선에 흐르는 무효 전력을 작게 하면
변압기 손실이 경감된다.

[ 배전선 손실 경감 ]
배전선에서 손실되는 전력도 전류의 제곱에 비례하므로 배전선에 흐르는 무효 전력을 작게하면 배전선 손실이 경감된다.

[ 설비용량의 여유 발생 ]
역률을 개선하면 무효 전력의 감소분 만큼 설비용량에 여유가 생긴다. 예로 1000KVA의 변압기에 역률 80%인 부하인 경우
800KW가 한도이지만 역률이 100%인 부하는 1000KW까지 사용할 수 있고 200KVA의 여유가 발생한다.

[ 전압 강하의 개선 ]
배전선 및 변압기에 무효 전류가 흐르면 전압 강하가 증가되는데 역률을 개선하게 되면 무효 전류가 감소하므로 전압
강하가 개선된다.

[ 전력 요금 경감 ]
한전에서는 한전 설비의 효과적인 활용을 위해 전기 요금에 역률 요금 제도를 두고 있으며 역률이 낮으면 가산금을 내고
역률이 높으면 전기요금을 할인하여 주고 있다.
젼력요금 = 기본요금 + 사용량요금 + 역률요금
역률요금 = 기본요금 X (1+ (90-역률)/100)

3. 콘덴서의 부속기기
 
[ 방전코일 ]
콘덴서를 회로에서 개방하였을때 잔류 전하에 의한 위험방지와 재 투입할 때 콘덴서에 과전압이 걸리는 것을 방지하기
위해 설치하고 방전코일의 성능은 아래와 같아야 한다.
- 고압의 경우 개방 후 5초 이내에 50V 이하
- 저압의 경우 개방 후 3분 이내에 75V 이하

[ 직렬리엑터 ]
역률 개선용으로 콘덴서를 사용하면 콘덴서에 고조파 유입시 콘덴서의 용량성 때문에 전류 파형의 왜곡을 확대하는 수가
있고 일반 3상 회로에서 제5고조파에 대응하여 직력리엑터의 용량을 6%를 적용하고 있다.

발전기


 전력용케이블

1. 전력용케이블

주로 전기전도가 좋은 구리 도체 연선을 절연물로 피복한 것을 절연전선이라고 하고, 절연피복 위에 보호 쉬스를 한겹 더한 것을 케이블이라고 부르며 케이블은 구조상 절연 전선에 비해 기계적.전기적으로 안전하므로 직접 노출 시공도 가능하고 활용 범위가 크므로 간선 계통은 거의 케이블로 시공한다.

2. 전력케이블의 종류



22.9KV 급까지는 XLPE 절연 케이블이 주종을 이류고 154KV 이상에서는 OF 케이블이 사용되었으나 절연 기술의 발달로 345KV 급까지 XLPE 절연케이블이 사용되고 있다. 여기에서는 600V 이하의 저압 케이블의 용도 정도만 설명하겠다.

 

CV케이블 (XLPE 절연 PVC 쉬스 케이블)
과거에 VV케이블 EV케이블등이 사용되었으나 전기적.물리적 특성이 우수한 CV케이블이 주종을 이루에 되었다. CV케이블은 구리도체 연선을 XLPE로 절연하고 비닐 쉬스를 씌운 구조로 가장 많이 사용하고 있다.

TFR-CV케이블 (트레이용 난연 전력케이블)
트레이용 난연성 CV케이블을 말하는 것으로 LG 전선의 경우 F-CV로 표기하나 내용는 같은 것이다. 케이블 트레이는 전선관에 비해 화염에 노출되기 쉽고 연소의 확대가 용이하므로 케이블 트레이에는 난연성이 검증된 트레이용 난연성 케이블이 사용되어야 한다.

HFCO케이블 (저독성케이블)
화재시 인명피해 양상을 보면 직접 불꽃에 노출되어 사망한 경우보다 유독 가스에 질식되어 사망한 경우가 많다. HFCO케이블은 화재시 연기가 작고 연기 중 유독가스 발생이 작은 피복 재료를 사용한 케이블을 말하며 공동구, 지하가 등에는 HFCO 케이블을 적용해야 한다.

FR-8, FR-3 (소방용 내화 케이블)
방재용 전력 간선에 사용되는 케이블로 화재시 케이블 피복이 소실되더라도 전력 공급이 가능하도록 도체위에 운모 등의 무기질 절연체로 감싼 구조의 케이블로 강전용은 FR-8로 약전용은 FR-3로 불린다.

TFR-8
FR-8 케이블을 트레이를 사용할 수 있도록 난연성 시험을 받은 것으로 케이블 트레이에는 TR-8을 사용해야 한다

3. 특고케이블의 종류
절연방식에 따라 OF케이블과 CV케이블로 대별할 수 있고, 20KV급 인입선으로는 CV케이블이 사용되고 있다.

[ CV와 CNCV의 차이점 ]
① CV케이블
도체를 XLPE로 절연하고 차폐테이프를 감고 비닐로 피복한 구조로 3.3KV, 6.6KV, 22KV에 사용한다.

② CNCV케이블
구조는 CV케이블과 비슷하나, 차폐층을 강화하여 다중접지 선로의 중성선과 공용하도록 한 구조의 케이블로 22.9KV-Y선로에 사용한다.

[ CV케이블의 22.9KV-Y 적용시 문제점 ]
지락시 지락전류를 흘릴 수 없으므로 별도의 중성선이 필요하다.
지락시 동축상에 중성선이 있는 CNCV보다 유도장애가 크다.
수트리에 약해 케이블 사고가 종종 일어난다.
따라서 인입선이 CV케이블로 시공된 곳은 CNCV수밀형으로 교체할
   필요가 있다.


 전력안정화장치

1. UPS
UPS는 상용전원의 전압강하, 노이즈, 정전 등 전원교란에도 불구하고 중요 설비에 정상적인 안정된 전력을 공급할 목적으로 사용된다.

[ UPS의 중요성 ]
상용전원의 전력 계통은 끊임없이 발전되고 정비되어 현재 정전회수와 계속 시간은 현저히 감소되었으나 낙뢰나 태풍 등의 자연 현상에 기인하는 고장을 완전히 없앨 수는 없다.
반면 부하설비는 전력전자 기기의 보급이 확대됨에 따라 양질의 전력을 요구하고 있으며 특히 컴퓨터 설비 등의 전원 이상은 큰 사회적 혼란은 초래하기도 한다. 이러한 이유로 은행, 증권, 공항, 경찰, 방송사 등을 비롯한 전산기기, 통신기기 등에 UPS는 꼭 필요한 설비가 되었다

 2. UPS의 구성
[ UPS 원리 ]
UPS는 상용전원의 교류 전원을 정류하여 직류로 변환 시킨 후 다시 깨끗한 교류로 변환시켜 부하기기에 공급하는 것으로 직류부분에 축전지가 있으면 UPS 이고 축전지가 없으면 CVCF이다. 정전 보상 시간은 축전지의 용량에 의해 결정된다.

[ UPS의 종류 ]

① 회전형 :
전력전자 소자가 발전되기 전에는 M-G세트에 의한 회전형 UPS가 사용되었다

 

② 정지형 UPS
: 전력전자 소자의 발달로 1960년대부터 정지형 UPS가 사용되었으며 지금은 거의 정지형 UPS가 사용된다.
 
③ 다이나믹 UPS

회전 UPS에 디젤 엔진을 붙인 구조로서 순시전압 강하는 회전형 UPS 회전자의 플라이휠 효과로 보상하고 정전이 길어지면 디젤 엔진이 기동하여 전력 공급을 계속하는 것으로 대용량에서 정지형보다 유리하다

[ UPS의 비교 ]

구분

정지형

다이나믹형

크기중량

소형에서 유리

대형에서 유리

정전보상시간

축전지 용량 때문에 정전보상
시간이 짧아 백업용 발전기 필요

M-G세트에 디젤 엔진이 결합된 구조로
별도 백업 발전기 필요 없음

전기적 특징

고조파 발생, 과부하 내량 작음

고조파 발생이 없고 과부하 내량이 크다

유지보수

전력전자 소자의 발달로 유지보수
거의 불필요

구동부가 있어 정기적인 분해정비가 필요함

* kimswed님에 의해서 게시물 이동되었습니다 (2010-07-16 13:57)
베트남두산엔진정비소

베트남두산엔진정비소

발전기 고장 유무 진단서비스 를 첨단장비로 검출해낼수있습니다.  엔진 정비소 대표전화  +84 908430716                   동기발전기의 특성       1. 무부하 포화곡선 및 단락곡선   1) 무부하 포화곡선  E=4.44fNok(V)에서 발전기가 정격속도에서 무부하로 운전하고 있는 경우 유기기전력은 자속 Φ에 비례한다. 그러나 무부하의 경우 자속은 계자기자력에 의해서만 정해지므로 무부하유기기전력과 계자기자력(계자전류)과의 관계곡선을 얻을 수 있다. 이것을 무부하 포화곡선(No Load Saturation) 이라고 한다.   이 곡선은 전압이 낮은 부분에서는 유기기전력이 계자전류에 정비례하여 증가하지만, 전압이 높아짐에 따라 철심의 포화로 인하여 자기저항이 증가하여 일정기전력을 유기하는데 계자전류가 보다 더 많이 필요하기 때문에 그림 OQ와 같은 포화곡선이 된다. 이 그림에서 OP는 무부하포화곡선의 직선부를 연장한 직선이며, 이것을 공극선(air gap line)이라고 한다. 그림에서 점 A가 정격전압에 상당하는 점이 될 때 (시그마) o= ab/Aa 를 포화율(Satruation factor)이라 하고 이것으로 포화의 정도를 표시한다.   2) 단락곡선 동기기가 단자를 단락하고 정격속도로 운전하고 있는 경우 단락전류와 계자전류와의 관계를 표시하는 곡선이 단락곡선(Short circuit curve)이며 그림의 OR과 같은 직선이 된다.   2.  단락비(short circuit ratio) 동기발전기의 특성에 있어서 단락비의 특성은 중요하며, 무부하포화곡선과 단락곡선의 특성을 이용하여 산정하게 된다. 그림에서 정격속도에서 무부하정격전압 Vn을 유기하는데 필요한 계자전류를 Ifo라고 하고 3상 단락정격전류  In을 흐르게 하는 계자전류를  Ifs 하면 발전기의 단락비는 k= Ifo/Ifs = Oe/Oc 가 된다. 단락비= 무부하포화곡선에서 구한 정격전압에 대한 계자전류        단락곡선에서 구한 정격전류에 대한 계자전류   1) 단락비와 동기임피던스의 관계 동기임피던스는 전기자단자에서 본 등가리액턴스와 전기자권선의 실효저항의 Vector합이나, 전기자저항은 무시할 정도로 작다.    동기임피던스 Zs=V /root3 I(ohm)    백분율동기임피던스 %Zs= 동기임피던스강하 / 동기전압(1상) = InZs/(V/root3) = 1/K x 100%  (무부하정격전압 V'n을 유기하는데 필요한 계자전류를 공극선에서 구하면?‘1 가 된다. 여기서 ?1/?2를 불포화단락비(unsaturated short circuit ratio)라 하며, 전자의 Ifo/Ifs로 표시된 단락비를 포화단락비(saturated short circuit ratio)라 한다.)   2) 단락비의 특성 (1) 단락비란 정격속도에서 무부하 정격전압을 발생하는데 필요한 여자전류와 삼상 단락 시...
안전용품 하노이영업소

안전용품 하노이영업소

중고발전기.컴프레샤.지게차 현장즉석구매합니다.   한국상품 지원팀    Mr. Kim  +84 90843 0716             문:     안녕하세요? 전기모터부분 궁금사항이 있어 여쭙고자 글을 올립니다. 중국에 공장매각후 기존 60hz 모터를 어떻게가동하는지 물었더니 기존모터를 50hz로 바꾸어서 가동중이라는 애기를 들었습니다. 국내 60hz 모터의 내부코일등 어떻게 수정해서 50hz로 사용할수있는건지 궁금합니다. 1. 모터 자체 효율이나 동력전달하여 회전체의 효율에 변화가 없는지요? 2. 비용면은 대략 어느정도인지? 3. 저희는 쉽게 변환기를 사용할수있는데 굳이 주파수를 바꾸는게 더 효율적인지 ? 부탁드립니다. 답1, 60Hz의 기계(모터,형광등)를 50Hz로쓰려면 기계류 중에서 전기 부품이 관련이 되겠지요 A/C 모터류는 50 / 60 만큼 회전수가 감소 하겠지요 (공식 rpm = 120 f / p : f=hz, p=모터 극수) 회전수 감소가 미치는 영향만큼 파워나 작동 속도(콘베어등)를 감안하셔야 될것입니다 아마 D/C 모터류는 인버터 입력 허용 전원 사양을 확인하셔야 될것 같고 발열기기(전기히터류), 조명기기는 차이가 없을것 같고 형광등인 경우 형광등 갓속에 들어 있는 안정기의 입력 전기 사양을 확인하셔야 할것 같네요 대부분 전기 부품들이 입력 전원 사양이 명시되어 있으므로 확인하시면 정확할 것입니다 답2, 우리나라에서는 주파수가 60Hz로 통일되어 있으나, 일본과 중국 등 외국에서는 지역에 따라서 50Hz로 되어 있으므로, 국내제품을 외국에 가져가거나 해외에서 살다가 이사한 사람들은 50Hz의 기기를 60Hz에서 사용하는 경우, 기기의 작동에 큰 변화가 일어납니다. 가전제품의 경우 요즘 나오는 것은 정격전압 및 주파수가 110/220V, 50/60Hz 모두 사용가능한 제품들이 많으며 이러한 제품은 주파수에 관계없이 사용하면 아무런 문 제가 없습니다. 가전제품이 전압만 다른 경우는 트랜스를 사용하면 되지만, 주파수가 다를 경우에는 주파수를 쉽게 변환 시키기는 어렵습니다. 주파수가 각각다른 제품을 사용할 경우 해당 전기제품의 성능이 제대로 발휘되지 않으며 고장의 원인이 될 수 있으니 사용하지 않는 것이 좋습니다. 만약 예를들어 그냥 사용할 경우, 50Hz용 기기를 60Hz용에 사용할 경우 일반적으로 임피던스가 증가되고 전류는 감소하므로 수명이 길어 질 수 있으며, 60Hz용 기기를 50Hz용에 사용할 경우는 대체적으로 임피던스가 감소하고 전류는 증가하므로 수명이 짧아질 수 있습니다. 어떤 경우는 이상 동작으로 고장이 나실 수도 있습니다. 구입하실 경우 모니터 뒷면이나 전원 아답터에 전압에 관한 라벨(정격 전압을 표시하는 스티커가 붙은것)을 꼭 확인하여 정격전압 및 주파수가 110/220V, 50/60Hz 모두 사용가능한 제품들이 많으니 이런 제품의 모니터를 구입하세요. 답3: 주파수를 60hz에서 50hz로 바꾸면 회전수가 감소 합니다. 즉 N=...
BLUE RACK

BLUE RACK

Hanoi Office    +84 908430716                                     디지털 병렬 시스템   커민스에서 생산되는 발전기 세트에 설치되어 공급되는 PCC(Power Command Control)병렬 시스템은 타사의 추종을 불허하리 만큼 놀라운 성능과 기능을 가지고 있습니다. 디지털 병렬 PCC는 운전, 설치 및 운영이 간편하고, 마이크로 프로세서로 제어되는 PCC 시스템은 완벽한 동기운전과 부하부담을 통하여 그 성능과 기능을 인정받았습니다. 발전기의 보호가 별도의 계전기 없이 차단이 가능합니다. 또, 별도의 동기제어반없이 소프트웨어를 이용하여 동기운전, 자동부하분담이 가능하고 차단기 제어도 가능합니다. 위와 같이 구성요소가 적은 관계로 일반적인 병렬운전보다 빠르고 정확한 운영이 가능하고 고장이 적고 각국의 공인기관의 승인(UL, CSA, NFPA, IEC)을 획득하여 신뢰성을 인정받았습니다. 또 한전과의 병렬운전을 위하여 기본적으로 'External load set line'을 가지고 있어 완벽한 한전 병렬운전이 가능하여 일반 병렬과 같이 많은 부품으로 구성되지 않아 제어가 편리하고, 증설시 차단기와 'Load sharing line'을 가설하면 되도록 구성되어 시스템을 구성, 증설 등에 편리합니다.                 병렬운전시스템   커민스에서 생산되는 발전기 세트에 설치되어 공급되는 PCC(Power Command Control)병렬 시스템은 타사의 추종을 불허하리 만큼 놀라운 성능과 기능을 가지고 있습니다. 디지털 병렬 PCC는 운전, 설치 및 운영이 간편하고, 마이크로 프로세서로 제어되는 PCC 시스템은 완벽한 동기운전과 부하부담을 통하여 그 성능과 기능을 인정받았습니다. 발전기의 보호가 별도의 계전기 없이 차단이 가능합니다. 또, 별도의 동기제어반없이 소프트웨어를 이용하여 동기운전, 자동부하분담이 가능하고 차단기 제어도 가능합니다. 위와 같이 구성요소가 적은 관계로 일반적인 병렬운전보다 빠르고 정확한 운영이 가능하고 고장이 적고 각국의 공인기관의 승인(UL, CSA, NFPA, IEC)을 획득하여 신뢰성을 인정받았습니다. 또 한전과의 병렬운전을 위하여 기본적으로 'External load set line'을 가지고 있어 완벽한 한전 병렬운전이 가능하여 일반 병렬과 같이 많은 부품으로 구성되지 않아 제어가 편리하고, 증설시 차단기와 'Load sharing line'을 가설하면 되도록 구성되어 시스템을 구성, 증설 등에 편리합니다. 병렬운전시스템   PowerCommand™ Paralleling 기능 Master Control ...
발전기 A/S센타

발전기 A/S센타

                                        (1) MOTOR는 여러 가지 분류 방법이 있으나 전원상수에 의해 단상 MOTOR와 삼상 MOTOR로 분류되고 있습니다.   1) 단상 MOTOR     - 단상 전원은 일반 가정용의 상용 전원으로 한 상으로 되어 있습니다.     - 전원 자체만으로는 MOTOR가 회전되지 않기 때문에 기동을 위하여 CONDENSER를 보조 COIL에 연결하여 기동을       시킵니다.   2) 삼상 MOTOR     - 삼상 MOTOR는 동력으로 구분되며 전원의 각상 전압의 위상이 120°씩 틀어진 3개의 전원으로 되어 있습니다.     - 전원을 MOTOR에 연결하여 구동시키면 용이하게 회전자계가 일어나 기동이 됩니다.     - MOTOR의 효율도 높으며 기동 TORQUE도 비교적 큽니다. (2) MOTOR를 기능 면으로 나누게 되면 크게 3가지로 나눌 수 있습니다.   1) 일정한 속도로 운전하는 MOTOR     ① INDUCTION MOTOR     - AC 소형 MOTOR의 대표적인 MODEL이며, 연속적으로 사용 할 수 있습니다.     - 단상용 CONDENSER RUN INDUCTION MOTOR와 삼상용 INDUCTION MOTOR의 2종류가 있습니다.     - LEAD WIRE TYPE과 TERMINAL BOX TYPE의 두 가지 종류가 있습니다.     ② REVERSIBLE MOTOR     - 단상용 CONDENSER RUN INDUCTION MOTOR입니다.     - 외관구조는 INDUCTION MOTOR와 거의 같지만 MOTOR의 회전 방향을 간편하게 역전시킬 수 있도록 간이       BRAKE봉을 MOTOR내부에 취부하여 정·역 운전을 자주 반복하여 사용할 때 적합합니다.     2) BRAKE 기능이 있는 MOTOR      ① 電磁 BRAKE 부착 MOTOR     - 無勵磁 作動型 電磁 BRAKE를 내장한 MOTOR입니다.     - 璪이 확실히 작동하여 유지력을 얻을 수 있습니다.     - 제동의 작동은 전원이 고장 일 때에 작동하므로 안전하게 사용하는 BRAKE로 적합합니다.     ② BRAKE PACK SB SERIES     - INDUCTION MOTOR, REVERSIBLE MOTOR 전용의 순시제동용 회로의 電子 BRAKE입니다.     - 유접점 BRAKE PACK과 무접점 BRA...
HYUNDAE G4DT

HYUNDAE G4DT

  ::: DIESEL ENGINE GENERATING SET :::                             GM4AK(FOR MARINE), G4DT(FOR LAND)   Diesel Engine - Type : 4-stroke, 4-cylinder, vertical, fresh water-cooling diesel engine - Continuous output : 74PSx1800RPM, 54PSx1500RPM - Cylinder bore x stroke : 100mmx105mm(3.94x4.13in) - Displacement : 3298 cc (201.3 cu. inch) - Aspirator : Natural aspirator Generator - Continuous output : 54kWx1800RPM, 40kWx1500RPM - Voltage : 220V, 380V, 440V - Phase x Wire : 3phasex4wire - Power factor : 0.8 - Insulating class : H   Model : GM4AK(FOR MARINE), G4DT(FOR LAND) Continuous Output : 40KW x 1,500RPM, 54KW x 1,800RPM   -Approval by the Korean Institute of Ship Safety & technology.-Acquired ISO 9001.-Acquired "Q" marking from government.-Acquired "GQ" marking from government.   1. Stable output about 3 % load-regulation.2. High output with the comparison of the same class diesel generators.3. Economical generators and parts, easy maintenance.4. Best designed and manufactured of all auxiliaries engines. Available for multi purpose from overland power to power supply,to emergency power (Special order and manufacture at low cost).5. Large capacity heat exchanger under the tropical zone for the safe operation.6. Use of high quality engine protection devices and instrument panels.    ▶부도체[不導體] (Non-conductor) 전기를 거의 통과시키지 않는 것. 불량도체라는 말. ▶부싱변류기[부싱變流器] (Bushing type current transformer) 절단형차단기의 붓싱(bushing)등을 이용하여 그 철심의 2차측에 권선을 하여 변류기로 한 것인데 1차전류 100A 이상이 아니면 오차가 많으며 또 2개의 변류기의 2차측을 직렬로 하여 사용하면 오차를 적게할 수 있다. 투관형변류기(套管形變流器)라고도 한다. ▶V결선[V結線] (V-connection) 삼각형결선의 1상분을 제거한 결선법인데 변압기의 결선 등에 흔히 사용된다. ▶V곡선[V曲線] (V-curve) 동기기에 있어서 전기자전류(電機子電流)를 종축으로 여자전류(勵磁電流)를 횡축으로 한 곡선인데 위상특성곡선(位相特性曲線)이라고도 하며 V자형을 이루고 있는 것. ▶VA 볼트암페어(Volt-Ampere)의 약자. ▶부하[負荷] (Load) ① 전력 또는 동력을 소비하는 것. 그 전력 또는 동력을 가리키기도 한다. ② 전력을 소...
POWERPLANT KOREA

POWERPLANT KOREA

      On the basis of long experience in the fields of electric facility maintenance, KPS has performed dismantling project for reusing since 1998. Dismantling electric facilities is one of specialties of KPS, specializing in the maintenance of power plant facilities     - Gas Turbine and Auxiliary Equipments - Steam Turbine and Auxiliary Equipments - Gantry Crane - Main & Auxiliary Transformer - Circuit Breaker - Packing and Crating- Temporary Port Construction- Temporary Bridging and Detour Construction for Equipment Transportation - Heavy Equipment Transportation     Kunsan Combined Cycle Power Plant   - Placing an Order : IBC (U.S.A.) - Period of Performance : 1998.09.16∼1998.12.31- Services provided   ·Gas Turbine (50Mw) 4 units and additional equipment dismantlement and removal ·Steam Turbine (100Mw) 1 unit and additional equipment dismantlement and removal ·Gantry Crane dismantlement and removal ·Main & AUX. Transformer dismantlement and removal ·Circuit Breaker dismantlement and removal ·Port establishment·Dismantlement equipment packaging and transportation   Yeongwol Combined Cycle Power Plant   - Placing an Order : IBC (U.S.A.)- Period of Performance : 1998.12.14∼1999.03.15- Services provided   ·Gas Turbine (50Mw) 4 units and additional equipment dismantlement and removal combined cycle·Steam Turbine (100Mw) 1 unit and additional equipment dismantlement and removal ·Dismantlement equipment packaging·Equipment transportation bridge supplementation and detour construction (restoration after completion)·Dismantlement equipment transportation           Midland Power Business Team, Power Plant Business Dept. vietnam contact   Tel : 84-908430716  Mr/Kim   * kimswed님에 의해서 게시물 이동되었습니다 (2010-07-16 13:58)
HYUNDAE G6D2T

HYUNDAE G6D2T

::: DIESEL ENGINE GENERATING SET :::                             GM6AZ(FOR MARINE), G6D2T(FOR LAND)   Diesel Engine - Type : 4-stroke, 6-cylinder, vertical, fresh water-cooling diesel engine - Continuous output : 225 PSx1800RPM, 207PSx1500RPM) - Cylinder bore x stroke : 130mmx140mm(5.12x5.51 in) - Displacement : 11149 cc (680 cu. inch) - Aspirator : TURBOCHARGED ASPIRATOR Generator - Continuous output : 179KWx1500RPM, 199KWx1800RPM - Voltage : 220V, 380V, 440V - Phase x Wire : 3phasex4wire - Power factor : 0.8 - Insulating class : H   Model : GM6AZ(FOR MARINE), G6D2T(FOR LAND) Continuous Output : 179KW x 1,500RPM, 199KW x 1,800RPM   -Approval by the Korean Institute of Ship Safety & technology.-Acquired ISO 9001.-Acquired "Q" marking from government.-Acquired "GQ" marking from government.   1. Stable output about 3 % load-regulation.2. High output with the comparison of the same class diesel generators.3. Economical generators and parts, easy maintenance.4. high efficiency and safety by using oil cooler of plate Model. 5. Safety with Large capacity heat exchanger under the tropics and severe operation. 6. High quality engine protection device and instrument panels.7. Various drawing and manufacture for the use of vessels' auxiliary engine, overland power and supply, emergency power and supply (Special order and manufacture at low cost).    수배전반 ( incoming panel )수배전에 필요한 각종 계기, 제어 개폐기, 보호 계전기 등을 안전하게 금속함에 설치한 것을 말하며 일반적으로 보수 점검이 용이하고 신뢰성이 높은 큐비클식(상자형) 수배전반을 많이 사용하고 있으며 설치 면적이 적고 기기의 구성이 간소하여 소형화 되며 보수 유지가 쉽고 고전압 기기가 모두 접지된 금속함에 넣어져 있으므로 사용자의 감전 재해, 기기의  고장에 의한 화재나 피해가 적고 간단하게  설비의 증설을 할수 있는 장점이 있음. 그러나 일정한 설계규칙에 의하여 규격화된 제품이므로 설비의 융통성이 적고  배전반의 교체나 변압기의 증설등이 비교적 어렵고 충전부가 금속함에 넣어져 있어 사용 상태로는 금속함의 내부 점검은 위험하므로 이 경우에는 정전하지 않고는 곤란한 점이 있다. 큐비클식 고압 수전설비의 종류로는 수전설비용량 1,000KVA이하에 ...
SEBANG BATTERY

SEBANG BATTERY

Good day. I hope your business is sailing very smoothly.   This is Ben KIM from GLOBAL BATTERY in Korea. It is my pleasure to introduce my company and products.   I as a representative of GLOBAL BATTERY guarantee the quality of our products and their performance.   As you know very well we GLOBAL BATTERY Co., Ltd., are the leading manufacture and company in battery industry in Korea. VRLA, AGM, GEL, Flood and Ni-MH are available.   In this time we have special price for 12V, Sealed Lead Acid Battery (AGM) batteries. I would like to let you know the special price. Please take a look.   As below the quotation, these prices are our latest and best price. This is based on one 20ft container at least.     ※12V, Sealed Lead Acid Battery (AGM)                                                (Currency : USD) ITEM Ah - VOLTAGE UNIT AMOUNT OTHER ESH30 30ah 12V 36.91   ESH40 40ah 12V 39.28   ESH65 65ah 12V 56.34   ES80H 80ah 12V 86.70   ES100H 100ah 12V 95.65 Only dimension is different. ESH100 100ah 12V 98.77 ESH120 120ah 12V 123.75   ESH130 130ah 12V 126.06   ESH150 150ah 12V 148.67   ESH200 200ah 12V 168.70                            F.O.B. Busan port Korea   I would like to let you know these prices are available for 2 months only.   By the way we have confidence in supporting you with timely delivery and best technical service.As the leading lead acid battery manufacture in Korea, we are always to be your supporter.   As a reliable manufacture, it is my pleasure to establish business with your esteemed company. We are expecting to be your long term reliable partner with our best price and support.   For more information, please visit our web www.gbattery.com   I look forward your early and positive response.     Thank you for your attention.     Warmest Regards Ben KIM Deputy Manager      =...
KPS KOREA

KPS KOREA

  Since starting planned outage maintenance of southern thermal power plant in Baghdad, Iraq in 1982, KPS took on the following rehabilitation project of Dibis power plant in Iraq, technology service for Kwangtung nuclear power plant in China, rehabilitation project of Malaya thermal power plant in the Philippines, operation and maintenance of Tawau diesel power plant in Malaysia, seawater cooling system O&M in Saudi Arabia and consultation about the establishment of maintenance company in Indonesia. What's more, KPS demonstrated its perfect state-of-the-art technology to the world by successfully completing operation & maintenance of GMR diesel power plant in India, planned outage maintenance (turbine / generator) of Bayswater and Eraring thermal power plants in Australia, long term maintenance service of Ilijan CCPP(Combined Cycle Power Plant) in the Philippines, commissioning service of TBP in India, Termonorte in Brazil and Fujairah in the United Arab Emirates, seawater pipe replacement of Quezon power plant in the Philippines and the relocation of Artika diesel power plant in Indonesia. In 1998, beginning with O&M service to GMR diesel power plant, KPS completed O&M contract with Vemagiri combined gycle Chanderiya, Balco and Jalsuguda coal fired power plants in India.In Australia, KPS won open bigging against globally recognized competitors for long term maintenance projects on the Eraring ane Bayswater coal fired power plant. While negotiating for various projects, KPS contracted an operation and maintenance agreement with the Darhaki combined cycle power plant in Pakistan worth around 100million dallars, the largest contract amount for an operation & maintenance service. KPS opened up a new area in the overseas nuclear power plant maintenance by performing refueling services for Angra NPP(Nuclear Power Plant) in Brazil and North Anna NPP in the USA, QDA(Qualified Data Analyst) services for Salem and Diablo Canyon NPP in the USA and GTSP(Guide Tube Support Pin) replacement services for Tihange NPP in Belgium and Krsko NPP in Slovenia.In addition, KPS has successfully fulfilled sophisticated plant services such as tube-plugging of steam generators using Remotely Operated Service ArmⅢ(ROSAⅢ), foreign object search & retrieval (FOSAR) in the secondary side of steam generators and refurbishment of reactor coolant pump seals. Our o...
HYUNDAE G4D

HYUNDAE G4D

::: DIESEL ENGINE GENERATING SET :::                             GM4AF(FOR MARINE), G4D(FOR LAND)   Diesel Engine - Type : 4-stroke, 4-cylinder, vertical, fresh water-cooling diesel engine - Continuous output : 54PSx1800RPM, 45PSx1500RPM - Cylinder bore x stroke : 100mmx105mm(3.94x4.13 in) - Displacement : 3298 cc (201.3 cu. inch) - Aspirator : Natural aspirator Generator - Continuous output : 40KWx1800RPM, 33kWx1500RPM) - Voltage : 220V, 380V, 440V - Phase x Wire : 3phasex4wire - Power factor : 0.8 - Insulating class : H   Model : GM4AF(FOR MARINE), G4D(FOR LAND) Continuous Output : 33KW x 1,500RPM, 40KW x 1,800RPM   -Approval by the Korean Institute of Ship Safety & technology.-Acquired ISO 9001.-Acquired "Q" marking from government.-Acquired "GQ" marking from government.   1. Stable output about 3 %load-regulation2. High output with the comparison of the same class diesel generators3. Economical generators and parts, easy maintenance4. Best designed and manufactured of all auxiliaries engines. Available for multi purpose from overland power to power supply,to emergency power. (Special order and manufacture at low cost)5. Large capacity heat exchanger under the tropical zone for the safe operation6. Use of high quality engine protection devices and instrument panels     [ 피뢰기의 기능 ]피뢰기는 선로를 타고 들어오는 이상전압을 신속히 대지로 방류하여 전력기기를 보호하는 기기이다.      [ 피뢰기의 동작 책무 ] ∵ 이상전압 침입시 신속하게 방전할 것∵ 이상전류 통전시 단자전압을 일정전압 이하로 억제할 것∵ 이상전압 해소 후 속류를 차단하여 자동 회복할 것∵ 반복 동작에 대해 특성이 변하지 않을 것 [ 피뢰기를 신설하여야 하는 장소 ] - 전기설비기술기준 제46조∵ 발전소,변전소 또는 이에 준하는 장소의 가공전선 인입구 및 인출구∵ 가공전선로에 접속하는 기준 제32조의 배전용변압기의 고압측 및 특별고압측∵ 고압 및 특별고압 가공전선로로 부터 공급을 받는 수용장소의 인입구∵ 가공전선로와 지중전선로가 접속되는 곳 [ 피뢰기의 적용 ] ※ 피뢰기의 정격 전압  전 력 계 통 피뢰기 정격 전압 (KV) 전압(KV) 중성점 접지 변전소 배전선로 345 유효접지 288 ...
KHCK cummins

KHCK cummins

Frequency 50Hz CUMMINS Engine Model Standby(KVA/KW) Prime(KVA/KW) KH-C28 28KVA/22KW 25KVA/20KW 4B3.9-G1 KH-C40 41KVA33KW 38KVA/30KW 4BT3.9-G1 KH-C48 47KVA/37.4KW 43KVA/34KW 4BTA3.9-G KH-C55 55KVA/44KW 50KVA/40KW 4BTA3.9-G2 KH-C65 65KVA/52KW 60KVA/48KW 4BTA3.9-G2 KH-C103 103KVA/82KW 94KVA/75KW 6BT5.9-G1 KH-C125 125KVA/100KW 115KVA/92KW 6BTA5.9-G2 KH-C142 143KVA/114KW 130KVA/104KW 6BTAA5.9-G2 KH-C175 175KVA/140KW 160KVA/128KW 6CTA8.3-G2 KH-C200 200KVA/160KW 181KVA/145KW 6CTA8.3-G2 KH-C220 220KVA/176KW 200KVA/160KW 6CTAA8.3-G2 KH-C275 275KVA/220KW 250KVA/200KW NT855-GA KH-C275D 275KVA/220KW 250KVA/200KW 6LTAA8.9-G2 KH-C312 312KVA/250KW 285KVA/228KW NTA855-G1A KH-C350 350KVA/280KW 320KVA/256KW MTAA11-G3 KH-C358 358KVA/286KW 325KVA/260KW NTA855-G1b KH-C375 375KVA/300KW 350KVA/280KW NTA855-G2A KH-C395 394KVA/315KW 350KVA/280KW NTA855-G4 KH-C412 412KVA/330KW 375KVA/300KW NTAA855-G7 KH-C500 500KVA/400KW 450KVA/360KW KTA19-G3 KH-C550 550KVA/440KW 500KVA/400KW KTA19-G4 KH-C625 625KVA/500KW NA KTAA19-G5 KH-C688 688KVA/550KW NA KTAA19-G6 A KH-C825 825KVA/660KW 750KVA/600KW KTA38-G2 KH-C880 880KVA/704KW 800KVA/640KW KTA38-G2A KH-C1000 1000KVA/800KW 910KVA/728KW KTA38-G2A KH-C1100 1100KVA/880KW 1000KVA/800KW KTA38-G5 KH-C1125 1125KVA/900KW 1025KVA/820KW KTA38-G5  cummins generator   export/import contact  Vietnam  84-908430716  Mr/ kim Droop 운전Droop(Speed Regualtion) 운전은 발전기가 계통에 연결되어 운전 시 계통 주파수에 맞추어 원동기(Turbine)의 속도가 조정(또는 주파수) 되어 운전하는 것으로 발전기가 계통에 연결되어 있을 때에는 계통주파수에 따라 원동기(Turbine) Governer Cntroller의 명령에 의한 Valve 또는 Gate으 개폐 대소에 따라 원동기(Trubine)의 속도가 조정(즉, 발전기의 출력 주파수)이 된다.발전기가 계통과 연결되어 있지 않을 경우에는 감당하고 있는 load가 발전기 정격출력보다 클 경우에는 발전기 출력 주파수(Turbine 속도)가 감소하며, 부하가 발전기 출력보다 작을 때는 발전기 출력주파수 즉 터빈의 속도가 증가하게 된다. 이 경우 발전 출력은 Reference 출력(Pre-setvalue)을 변경하여 발전출력의 조정이 가능하게 된다. Isochronous M...
KHCK Deutz

KHCK Deutz

Deutz--KHCK D Series Generating Set Technical Data (50HZ) (28kVA-150kVA) Model Frequency 50Hz DEUTZ Diesel Engine Standby(KVA/KW) Prime(KVA/KW) KH-D30 30/24 27.5/22 D226B-3D KH-D34 34/27 31/25 D226B-3D KH-D48 48/37.5 42.5/34 TD226B-3D KH-D65 65/52 60/48 TD226B-4D KH-D142 142/114 130/104 TBD226B-6D KH-D165 165/132 150/120 TBD226B-6D5 과전류계전기(過電流繼電器 : over current relay) 전류의 크기가 일정치 이상으로 되었을 때 동작하는 계전기이며 특별히 지락사고 시 지락전류의 크기에 응동하도록 한 것을 지락과전류계전기라 하고 일반 과전류계전기를 OCR(over current relay), 지락과전류계전기를 OCGR(over current ground relay)이라 함 과전압계전기(過電壓繼電器 : over voltage relay) 전압의 크기가 일정치 이상으로 되었을 때 동작하는 계전기이며 지락사고 시 발생되는 영상전압의 크기에 응동하도록 한 것을 특히 지락과전압계전기라하고 각각 OVR(over voltage relay) 및 OVGR(over voltage ground relay)이라 함 부족전압계전기(不足電壓繼電器 : under voltage relay) 또는 부족전압계전기 UVR 전압의 크기가 일정치 이하로 되었을 때 동작하는 계전기이며 저전압계전기라 부르기도 함 부족전류계전기(부족전류계전기 : under current relay) 전류의 크기가 일정치 이하로 되었을 때 동작하는 계전기이며 일반적으로 보호 목적보다는 제어목적으로 사용되는 경우가 많다. 전력계전기(電力繼電器 :  power relay) 전력의 크기가 일정치 이상으로 되었을 때 동작하는 계전기로 교류용은 유효전력계전기와 무효전력계전기 2종류가 있다. 유효전력계전기(有效電力繼電器 : active power relay) 전력의 유효성분(VIcosθ)의 크기에 따라 응동하는 계전기 무효전력계전기(無效電力繼電器 : reactive power relay) 전력의 무효성분(VIsinθ)의 크기에 따라 응동하는 계전기 방향계전기(方向繼電器 : directional relay) 전압 vector를 기준으로 전류의 흐르는 방향이 일정범위 안에 있을 때 응동하는 계전기이며 일반적으로 전류의 방향이 동작범위 이내에서도 전압?전류의 적(積)이 일정치 이상에 달했을 때 동작하도록 되어 있어 전력방향계전기라 부르기도 한다. 기준으로 하는 것을 전압 vector가 아닌 일정방향의 전류vector로 사용하는 경우도 있으며 이러한 기준량을 극성량(極性量 : polarizing voltage 또는 polarizing current)라 하고 인가되는 극성량 및 전류의 종류에 따라 방향과전류계전기 및 지락방향과전류계전기가 있다. 방향과전류계전기(方向過電流繼電器 : directional over current relay : DOCR) 선간전압을 기준으로 전류의 방향이 일정범위 안에 있을 때 응동하는 것으로 loof 계통의 단락사고보호용으로 사용된다. 지락방향...
HYUNDAE G6D

HYUNDAE G6D

::: DIESEL ENGINE GENERATING SET :::                     GM6BR(FOR MARINE), G6D1(FOR LAND)   Diesel Engine - Type : 4-stroke, 6-cylinder, vertical, fresh water-cooling diesel engine - Continuous output : 117PSx1800RPM, 99PSx1800RPM) - Cylinder bore x stroke : 118mmx115mm(4.65x4.53 in) - Displacement : 7545 cc (460 cu. inch) - Aspirator : Natural aspirator Generator - Continuous output : 86KWx1800RPM, 73KWx1500RPM) - Voltage : 220V, 380V, 440V - Phase x Wire : 3phasex4wire - Power factor : 0.8 - Insulating class : H   Model : GM6BR(FOR MARINE), G6D1(FOR LAND) Continuous Output : 73KW x 1,500RPM, 86KW x 1,800RPM   -Approval by the Korean Institute of Ship Safety & technology.-Acquired ISO 9001.-Acquired "Q" marking from government.-Acquired "GQ" marking from government.   1. Stable output about 3 % load-regulation.2. High output with the comparison of the same class diesel generators.3. Economical generators and parts, easy maintenance.4. high efficiency and safety by using oil cooler of plate Model. 5. Large capacity heat exchanger under the tropics for the safe operation.6. Use of high quality engine protection devices and instrument panels. 7. Best designed and manufactured of all auxiliaries engines. Available for multi purpose from overland power to power supply,to emergency power (Special order and manufacture at low cost).     차단기 KA수 구하는법 좀 알려주세요~   >>22.9Kv 에서 300KVA 변압기로... 600A짜리 메인MCCB 다음에  분기 차단기 2 P 50A 차단기를 사용할려는데 몇 KA 짜리를 써야되나요??     차단용량 산정 방법 (Calculated Way Of Frame) ■ 단락전류의 종류 전략 계통에 있어서 단락잔류를 구하는 경우, 그 값을 사용하는 목적은① 계통 차단기, 휴즈의 선정② 계전기의 조정③ 계통의 기계적 강도에 대한 고려④ 계통의 열적 강도에 대한 고려 등의 검사입니다.이와 같은 검사에 맞게 사용하는 단락 전류는 각기 다르며, 단락 전류의 표시 방법으로서, 표시하는 대칭 전류와 직류분을 포함하여 표시하는 비대칭 전류로 구분됩니다. ㆍ단락 전류 교류분 실효치 : l(rms/sym)단락 전류는 그림과 같이 교류분과 직류분으로 구성되어 있으며, 교류분 실효치로 표시되는 단락 전류를 말하며, ...
EGCON-ABC

EGCON-ABC

CONTROL PARTS     |     ABC  (Automatic Battery Charger) MODEL : SMP FUNCTION1. constant voltage, constant current switching charge2. Select S/W between Floating / Equalizing charge 3. When Input power off, Battery discharge is closed4. Terminal of force-charge in battery discharge time5. Protect for wrong connection of the output line6. Within 1% output Volt reply7. Anti Humid & vibration treatment by silicon coating SPEC.1. Output : 12/24Vdc, 5A, 10A2. Input : 220Vac, Single Ph, 50Hz/60Hz both3. Size (mm) : W130*H160 *D534. distance[attach](mm) : W60*H150, 5¢ x45. Weight : 880g MODEL : SMF FUNCTION1. Constant voltage, constant current switching charge2. Function of Equalized charge time setting by timerAfter charge, automatically back to float charge3. When Input power off, Battery discharge is closed4. Terminal of force-charge in battery discharge time (V+)5. Protect for wrong connection of the output line6. Within 1% output Volt reply7. Contact of alarm for Over Charge,Over discharge SPEC.1. Output : 12/24Vdc, 5A/10A/20A2. Input : 220Vac, 50/60Hz both available3. Size (mm) : W170*H240*D2504. Weight: 2.7 KG MODEL : SMW FUNCTION1. Constant voltage, constant current switching charge2. Function of Equalized charge time setting by timerAfter charge, automatically back to float charge 3. When Input power off, Battery discharge is closed4. Terminal of force-charge in battery discharge time (V+)5. Protect for wrong connection of the output line6. Within 1% output Volt reply7. Contact of alarm for Over Charge,Over discharge SPEC.1. Output : 12/24Vdc, 5A/10A/20A2. Input : 220Vac, 50/60Hz both3. Size (mm) : W170*H270*D1304. distance[attach](mm) : W100*H255, 5¢ x45. Weight : 2.7 KG MODEL : DCF FUNCTION1. constant voltage, constant current switching charge2. Function of Equalized charge time setting by timerAfter charge, automatically back to float charge 3. Charge 2 piece of battery at the same time4. When Input power off, Battery discharge is closed5. Protect for wrong connection of the output line6. Within 1% output Volt reply7. Contact of alarm for Over Charge,Over discharge,breakdown8. Broadcast, telecommunication.etc which are using backup battery SPEC.1. Output : 12/24Vdc, 20A2. Input : 220Vac, 50/60Hz both3. Size (mm) : W300*H350*D2504. Weight : 6Kg 차단기 (Circui...
HYUNDAE G6D2TA

HYUNDAE G6D2TA

::: DIESEL ENGINE GENERATING SET :::                     GM6AC(FOR MARINE), G6D2TA(FOR LAND)   Diesel Engine - Type : 4-stroke, 6-cylinder, vertical, fresh water-cooling diesel engine - Continuous output : 315PSx1800RPM, 288PSx1500RPM - Cylinder bore x stroke : 133mmx155mm - Displacement : 11149 cc (680 cu. inch) - Aspirator : TURBOCHARGED ASPIRATOR Generator - Continuous output : 126kWx1800RPM(112kWx1500RPM) - Voltage : 220V, 380V, 440V - Phase x Wire : 3phasex4wire - Power factor : 0.8 - Insulating class : H   Model : GM6AC(FOR MARINE), (FOR LAND) Continuous Output : 219KW x 1,500RPM, 232KW x 1,800RPM   -Approval by the Korean Institute of Ship Safety & technology. -Acquired ISO 9001. -Acquired "Q" marking from government. -Acquired "GQ" marking from government.   1. Stable output about 3 % load-regulation.2. High output with the comparison of the same class diesel generators.3. Economical generators and parts, easy maintenance.4. high efficiency and safety by using oil cooler of plate Model. 5. Safety with Large capacity heat exchanger under the tropics and severe operation. 6. High quality engine protection device and instrument panels.7. Various drawing and manufacture for the use of vessels' auxiliary engine, overland power and supply, emergency power and supply (Special order and manufacture at low cost).     위의 그림을 보면 전선이 4가닥이 있습니다.  각각의 전선에 이름을 붙입시다. 즉, R, S, T ,N 이라고.   위 전선의 사용전압을 440/ 220 볼트 혹은 380 /220 볼트 혹은 그 어떤 다른 전압으로도 정할 수 있으나,  여기서 380 /220 볼트를 선택하겠 습니다. 왜!  우리 주위에서 흔히 사용하므로.  위 전선 호상간 ( 혹은 상호간)의 전압을 재어 보면 R-S 간 = 380볼트 S-T 간 = 380 볼트 T-R 간 = 역시 380   R-N 간 =  S - N 간 =  T - N 간 = 220 볼트  자!  그림 하나를 더 살펴봅시다.   그림 1은 단상을 표시한 것입니다. 그림1에서의 전압원을   여러분이 그 실체를 굳이 인식하고 싶다면  발전기 혹은 변압기가 전압원에 해당합니다.  그림 1처럼 전압원이 하나인 것을 단상이라 하는데  그림 1에서 전선 AB간의 전압은 220 볼트일 수도 있고 380볼트일 수도 있고 ...
HYUNDAE G4BB

HYUNDAE G4BB

  ::: DIESEL ENGINE GENERATING SET :::                             GM4BB(FOR MARINE), G4BB(FOR LAND)   Diesel Engine - Type : 4-stroke, 4-cylinder, vertical, fresh water-cooling diesel engine - Continuous output : 21PSx1500RPM, 25PSx1800RPM - Cylinder bore x stroke : 91.1mmx100mm(3.58x3.93 in) - Displacement : 2607 cc (102.6 cu. inch) - Aspirator : Natural aspirator Generator - Continuous output : 15KWx1500RPM, 18KWx1800RPM) - Voltage : 220V, 380V, 440V - Phase x Wire : 3phasex4wire - Power factor : 0.8 - Insulating class : H   Model : GM4BB(FOR MARINE), G4BB(FOR LAND) Continuous Output : 15KW x 1,500RPM, 18KW x 1,800RPM   -Approval by the Korean Institute of Ship Safety & technology. -Acquired ISO 9001. -Acquired "Q" marking from government. -Acquired "GQ" marking from government.   1. Stable output about 3 %load-regulation 2. High output with the comparison of the same class diesel generators 3. Economical generators and parts, easy maintenance 4. Best designed and manufactured of all auxiliaries engines. Available for multi purpose from overland power to power supply,to emergency power. (Special order and manufacture at low cost) 5. Large capacity heat exchanger under the tropical zone for the safe operation 6. Use of high quality engine protection devices and instrument panels 전기용어 설명: ▶반한시-정한시특성[反限時-定限時特性] (Inverse definite time-limit characteristic) 동작에너지(energy)의 어떤 범위에서는 반한시특성이며 어느 정도를 넘으면 정한시특성이 되는 한시특성(限時特性). ▶발신음[發信音] (Dial tone) 자동전화교환기에서 가입자가 다이얼(dial)을 돌림으로써 생기는 소리. ▶발전기[發電機] (Generator;Dyname) ①전력을 발생하는 회전기로써 직류발전기(直流發電機), 동기발전기(同期發電機), 유도형발전기(誘導型發電機)로 대별하며 용도에 따라 종류나 형식이 여러 가지 있다. ②기계동력을 전력으로 변환하는 회전기. ▶발전기리액터[發電機리액터] (Generator reactor) 발전기 또는 변압기와 모선과의 사이에 연결되고 단락에 의한다. 기기권선의 장애(障碍)를 방지하는데 소용되는 한류(寒流) 리액터(reactor). ▶발전제동[發電璪] (Dynamo braking) 전동기를 선로에서 떼어 발전기로서 단자간에 접속한 저항중에 생기는...
EGCON-AVR

EGCON-AVR

CONTROL PARTS     |     AVR  (Automatic Voltage Regulator) MODEL : 635 FUNCTION1. Single Phase half-wave rectification2. A/S support3. Selection switch for generator capacity is included4. Selection switch 50Hz~60Hz frequency is included5. Low Frequency Protect Circuit is included6. Anti Over Voltage Circuit is included7. Noise filter (Input power type) is included SPEC.1. Output : 63Vdc, 5A2. Input power : Single Ph 220Vac(190~277), 50/60Hz3. Sensing Input :Single Phase,190~520Vac, 50/60Hz4. Size(mm) : W95*H160 *D375. distance[attach](mm) : W60*H150, 5¢ x46. Weight : 530g MODEL : 631 FUNCTION1. Single Phase half-wave rectification2. A/S support3. Selection switch for generator capacity is included4. Selection switch 50Hz~60Hz frequency is included5. Low Frequency Protect Circuit is included6. Anti Over Voltage Circuit is included7. Noise filter (Input power type) is included SPEC.1. Output : 63Vdc, 10A2. Input power : Single Ph 220Vac(190~277), 50/60Hz3. Sensing Input :Single Phase,190~520Vac, 50/60Hz4. Size(mm) : W95*H160 *D375. distance[attach](mm) : W60*H150, 5¢ x46. Weight : 530g MODEL : 63P FUNCTION1. Single Phase half wave rectification2. Anti-humid and vibration by molding treatment3. Select S/W for 50/60Hz is included4. Selection switch for generator capacity is included5. Low Frequency Protect Circuit is included6. Anti Over Voltage Circuit is included7. Noise filter (Input power type) is included SPEC.1. Output: 63Vdc, 5A2. Input Power : Single Ph. 220Vac, 50/60Hz3. Sensing Input : Single Ph, 190~520Vac, 50/60Hz4. Size (mm) : W95*H160 *D375. distance[attach](mm) : W60*H150, 5¢ x46. Weight : 360g MODEL : FC1 FUNCTION1. Single Phase full wave rectification2. Parallel Running Function3. Select S/W for 50/60Hz is included4. Select S/W for Generator capacity is included5. Low Frequency Protect Circuit is included6. Detect Over voltage output7. Volt control is available extra controller8. Extra Huse for semicon protect is included9. Possible Input power from PMG or auxiliary winding SPEC.1. Output : 125Vdc, 6A2. Input PW : Single Ph 220Vac(190~277),50~125Hz3.Detached input :Single Ph,190-520Vac, 50/60Hz4. Size (mm) : W140*H200 *D405. distance[attach](mm) : W90*H190, 5¢ x46. Weight : 1.35Kg MODEL : FC2 FUNCTION1. Single Phase full wave rectifi...
HYUNDAE G6D7A

HYUNDAE G6D7A

::: DIESEL ENGINE GENERATING SET :::                             GM6CA(FOR MARINE), G6D7TA1(FOR LAND)   Diesel Engine - Type : 4-stroke, 6-cylinder, vertical, fresh water-cooling diesel engine - Continuous output : 400PSx1800RPM, 360PSx1500RPM - Cylinder bore x stroke : 130mmx140mm(5.12x5.51 in) - Displacement : 11149 cc (680 cu. inch) - Aspirator : TURBOSHAGED ASPIRATOR Generator - Continuous output : 304KWx1800RPM, 265KWx1500RPM - Voltage : 220V, 380V, 440V - Phase x Wire : 3phasex4wire - Power factor : 0.8 - Insulating class : H   Model : GM6CA(FOR MARINE), G6D7TA1(FOR LAND) Continuous Output : 265KW x 1,500RPM, 304KW x 1,800RPM   -Approval by the Korean Institute of Ship Safety & technology. -Acquired ISO 9001. -Acquired "Q" marking from government. -Acquired "GQ" marking from government.   1. Stable output about 3 %load-regulation 2. High output with the comparison of the same class diesel generators 3. Economical generators and parts, easy maintenance 4. Best designed and manufactured of all auxiliaries engines. Available for multi purpose from overland power to power supply,to emergency power. (Special order and manufacture at low cost) 5. Large capacity heat exchanger under the tropical zone for the safe operation 6. Use of high quality engine protection devices and instrument panels     주파수(周波數:Frequency)란 진동전류나 전파 또는 음파 등이 반사·굴절하여 파상으로 방향을 바꾸는 주기적 현상으로 그 주기적 파상 현상이 1초동안에 반복되는 횟수를 말합니다.독일의 물리학자 하인리히 루돌프 헤르츠(Heinrich Rudolf Hertz)가 전기진동의 실험에 의해 전자파의 존재를 확인하고 이것이 반사·굴절 등의 현상에서 완전히 광파와 같은 성질을 가졌음을 실증하였다고 합니다.주파수란 이와 같은 반사 굴절현상이 주기적으로 일정한 속도로 반복변동하는 상태(주기현상)가 1초동안에 몇번 반복되는가를 나타내는 수를 말하며 한편 진동수라고 합니다. 단위는 1초동안의 진동수가 1인 경우에는 1헤르츠(Hz) 또는 1사이클(c/s), 1초동안 1000회인 경우엔 1킬로헤르츠(KHz), 백만회를 메가헤르츠(MHz)라고 하며 극히 많은 진동수인 10억회는 기가헤르츠(GHz)라 부릅니다. 전파는 주파수가 낮을수록 파상의 파장이 길기 때문에 장파라고 하는데 편...
HYUNDAE G6D2TA2

HYUNDAE G6D2TA2

::: DIESEL ENGINE GENERATING SET :::                             GM6CA2(FOR MARINE), G6D2TA2(FOR LAND)   Diesel Engine - Type : 4-stroke, 6-cylinder, vertical, fresh water-cooling diesel engine - Continuous output : 440PSx1800RPM, 400PSx1500RPM - Cylinder bore x stroke : 133mmx155mm - Displacement : 12920 cc (680 cu. inch) - Aspirator : TURBOCHARGED Generator - Continuous output : 126kWx1800RPM(112kWx1500RPM) - Voltage : 220V, 380V, 440V - Phase x Wire : 3phasex4wire - Power factor : 0.8 - Insulating class : H   Model : GM6CA2(FOR MARINE), G6D2TA2(FOR LAND) Continuous Output : 294KW x 1,500RPM, 324KW x 1,800RPM   -Approval by the Korean Institute of Ship Safety & technology. -Acquired ISO 9001. -Acquired "Q" marking from government. -Acquired "GQ" marking from government.   1. Stable output about 3 % load-regulation. 2. High output with the comparison of the same class diesel generators. 3. Economical generators and parts, easy maintenance. 4. Best designed and manufactured of all auxiliaries engines. Available for multi purpose from overland power to power supply,to emergency power (Special order and manufacture at low cost). 5. Large capacity heat exchanger under the tropical zone for the safe operation. 6. Use of high quality engine protection devices and instrument panels.     차단용량 산정 방법 (Calculated Way Of Frame) ■ 단락전류의 종류 전략 계통에 있어서 단락잔류를 구하는 경우, 그 값을 사용하는 목적은① 계통 차단기, 휴즈의 선정② 계전기의 조정③ 계통의 기계적 강도에 대한 고려④ 계통의 열적 강도에 대한 고려 등의 검사입니다.이와 같은 검사에 맞게 사용하는 단락 전류는 각기 다르며, 단락 전류의 표시 방법으로서, 표시하는 대칭 전류와 직류분을 포함하여 표시하는 비대칭 전류로 구분됩니다. ㆍ단락 전류 교류분 실효치 : l(rms/sym)단락 전류는 그림과 같이 교류분과 직류분으로 구성되어 있으며, 교류분 실효치로 표시되는 단락 전류를 말하며, 차단기 및 FUSE를 선정하는 경우는 이 전류치에 의해 전류로 구분됩니다.   ㆍ 최대 비대칭 단락 전류 실효치 : l(rms/sym)직류분을 포함한 실효치로 표시되는 단락 전류를 비대칭 단락 전류 실효치라 하며, 이 전류는 단락 투입 위사에 따라 그 값이 변하게 됩...
HYDRO POWER KOREA

HYDRO POWER KOREA

            Especially, KPS has executed maintenance of many kinds of hydraulic generator and pumped storage power plant   systematically including Francis(Whacheon #1, 2, 3, 4/Cheongpyeong pumped storage #1, 2/Samrangjin pumped storage #1, 2/Muju pumped storage #1, 2), Kaplan(Chuncheon #1, 2/Cheongpyeong #1, 2), Propeller(Cheongpyeong #3) and Bulb(Paldang #1, 2, 3, 4).KPS has built maintenance records efficiently such as equipment specification, work procedures and facilities history using the MAPS(Maintenance Assister for Power Stations) that is a supporting system of power plant maintenance and it covers all facilities of hydro power plant, for example dam equipment, water intake equipment, waterway equipment and electrical equipment. Also, KPS makes assurance for the operation management of power generating facilities by reflecting the analysis of trouble the years before and the result of facilities diagnosis. In particular, KPS helps to life extention of facilities by performing perfect alignment with a large alignment equipment that is developed by ourselves. Futhermore, KPS guarantees stable availability of facilities through the prediction diagnosis maintenance system, the complete operation of planned outage maintenance, the enlargement of scientific process control, systematical education and training.     Maintenance during Commissioning Phase   It is a kind of maintenance that is performed general maintenance service in the process of construction such as installation, trial test, check of the abnormal part found in testing operation and its modification.   Routine Maintenance   It is a kind of maintenance that is offered preventive maintenance as well as corrective maintenance during the operation or the suspension to help the normal operation of facilities.     Preventive Maintenance   It is a kind of active maintenance to preserve the operation condition of facilities in the range of plan and to prevent the occurrence of functional failure in advance. Always KPS checks the operation condition of facilities and makes the walk-around inspection of priority and delicate facilities. Besides, a fault found by operating 『My Machine system』 is reflected in maintenance plan and KPS optimiz...